Krautkramer Usm 25 Operating Manual
Reports are produced in jpeg or bmp format so there is no need for special reading software. A simple on-board data logger to collect and save thickness measurements. State-of-the-art electronics, including digital amplifier, square wave pulser (optional) and digital filters for a wide range of application benefits. Features: SpotChecker “completes” our existing USLT product line for spot weld testing. It offers true portability with a rugged, environmentally protective housing. The key difference between this product and existing spot weld testing solutions is its size/weight, environmental protection and user friendly operating.
Technical Reference and Operating Manual. 5-25 Deleting a data set. 1-4 Issue 01, 04/2005 Krautkramer USM 32X. Baby & children Computers & electronics Entertainment & hobby Fashion & style. USM 35X Operating Manual 1 MB.
IMPORTANT: This instrument is to be used only for testing materials in an industrial environment. Any use for medical applications or any other purpose is not permitted. • Preface Important Ultrasonic Testing Guidelines Please read the information in this section before using your instrument. It is important that you understand and observe this information to avoid any operator errors that might lead to false test results.
You are productive from the moment you pick it up! Zte zxv10 w300 firmware update. Navigation is simplified using the proven graphical user interface (GUI) and the innovative joystick, allowing one-handed operation and fast and accurate adjustment. Other features allowing increased productivity are: A robust moulded rubber casing to withstand the harshest environments and significantly reduce downtime. The instrument is dust- and water-proof to IP67 and is tested to withstand shock and vibration.
The statement in the function box changes to TCG/DAC MODE OFF. Making Measurements 3.13 DGS Evaluation Mode (cont.) Using the DGS mode (Distance Gain Size), you can compare the reflecting power of a natural flaw in the test object with that of a theoretical flaw (e.g. A circular, disk-shaped equivalent reflector) at the same depth. You are comparing the reflecting power of a natural flaw with that of a theoretical flaw. Making Measurements 3.13 DGS Evaluation Mode (cont.) In addition to the influencing variables already mentioned, these other factors affect the curve shape: • sound attenuation • transfer losses • amplitude correction value • probe Also, the following probe parameters affect the curve shape: •.
Several functions are displayed on the screen. Use the joystick ( ) to select the function titled ORIENTATION, then press the center of the joystick ( ) to activate the function.
DAC/TCG, Echo Start and Angle functions - were left out, however, no compromises were made regarding the ultrasonic performance capabilities. The universal genius The USD 15 X represents the enhanced standard version of the product family offering all the extra features that you need for an easy reproducible ultrasonic testing in portable or stationary mode. These extras include DAC/TCG, reflector location using angle-beam probes, A-scan comparison, video output and many other fascinating features. Ryuichi sakamoto concert. With extra large display The USD 15 SX has a highresolution, extra large screen display. This enables you to obtain an,,almost analog' A-scan display of echo details with small calibration ranges or echo sequences from thin test objects, e.g.
When JISDAC is active, the instrument displays a line that represents echo peaks for constant reflectors at varying material depth. Making Measurements 3.16.1 Recording the JISDAC Curve (cont.) Note: When the first JISDAC reference point is stored, two measurement result boxes will be automatically set (if not already configured) to display SA and A%A values. Continue to record additional curve points, up to a maximum of 15 points (note that at least two JISDAC Curve points are required). When all of your points have been entered, select the FINISH function.
Echo) that is returned to the instrument from the material being tested. The series of echoes looks like the Radio Frequency (RF) signal shown in Figure 12 below.
Its ergonomic features include; Portability -Small size and weight, which allow the instrument to be easily operated in confined spaces and areas of difficult access. -Light enough to be carried throughout a whole day’s shift -Battery provides up to 5,5 hours operation. Can be recharged on- or off-board.
With square-wave pulser Though seemingly identical to the USD 15 SX, which has a spike purser (like the other instrument versions), the USD 15 SQ is provided with a variable square-wave initial pulse. This means that the probe is excited with its natural frequency. You will benefit from a considerable sensitivity increase of up to 12 dB, especially with operating frequencies of less than 2 MHz. Therefore, the instrument is particularly suitable for testing strongly sound attenuating and sound scattering materials.
General Information 1.5.1 Removing the SD Card To remove the SD card from its slot, proceed as follows: Access the SD card slot by pushing on the cover in the direction of the arrow and lifting the hinged cover. Press down of the SD card with your finger and then remove your finger quickly. General Information 1.5.3 Connecting the USB Port The connector closest to the hinge of the top compartment cover (see Figure 5 on page 13) is a Micro USB port. If you use a standard USB cable to connect the USM Go to a PC (no special drivers are required), the installed SD card will be added to the list of active drives on the PC. General Information 1.5.4 Connecting the I/O Port The connector furthest from the hinge of the top compartment cover (see Figure 5 on page 13) is an I/O port. This port serves a dual role: • Serial port pins - these are used strictly for factory service diagnostics.
Modern PC interfaces, including USB and wireless connection (WLAN, BlueTooth) Remote control like USLT 2000 Ease of use for untrained inspectors (Application Specific Software UltraLOG) Compatible with other USLT 2000 solutions Hot swap battery exchange for continuous operation Environmentally protected according IP65 Weight approx. 3.2 kg including batteries. Spectification: Storage Temperature -20 to +60 °C (-4 to +140°F) Operating Temperature 0 to +45 °C (32 to 113°F) Dimensions W 225 × H 314 × D 94 mm (W 8.85 x H 12.36 x D 3.7”) Weight Approx. 3.2 kg (7.05 lb) (Incl. Batteries) Protection Rating IP 65 Shock Resistance According to EN 600 68-2-27 Vibration Resistance According to IEC 600 68-2-6 Fc Display 8.4” TFT, SVGA, Touchscreen Control Devices 2 × Trackball with 2 Buttons Each, 6 Function Keys, Touchscreen Connections Probes 2 × LEMO 00 Triax Power Supply Unit 1 × LEMO 0S, 4-pin Socket Network 1 × RJ45 USB 4 × USB Type A Socket, 1 × USB Type B Socket Optional WLAN, Bluetooth Power Supply Operating Voltage 15 V DC Power Consumption Approx.
• Sensing & Inspection Technologies Ultrasonic USM Go Operator’s Manual P/N 1259801 Rev. • USM Go Ultrasonic Flaw Detector Operator’s Manual P/N 1259801 Rev. 1 July 2009 GESensingInspection.com ©2009 General Electric Company.
The USIP 40 is a precision, multi-channel ultrasonic testing instrument designed to deliver the utmost in inspection confidence. A variety of packaging options allow the USIP 40 to be configured as an ultrasonic box driven by a remote PC, an integrated rack mount instrument, or as a battery powered portable instrument. Combined with optional application-specific imaging and analysis tools, the USIP 40 offers the ultimate solution for all of your inspection needs. Available up to ultrasonic 10 channels Up to 20kHz PRF EchoMAX-never miss a shot Backwall echo attenuator Direct 3 axis encoder input Interface gate synchronizing for surface following Multi-language enabled Aerospace controlled configuration to GE P3TF22, P3TF35 and Rolls Royce RPS 705 Automatic gain control. The StressTel BoltMike III ultrasonically measures tension and clamp load of threaded fasteners. A large, bright, easy-to-read display; rapid calibration and setup; and automatic temperature compensation ensure fast, repeatable and accurate fastener tension measurements in many diverse applications.