Specifications: Wheel Diameter 28' Inlet Diameter 8' Exhaust Diameter 16' Max Power 4450 HP (3729 kW) Max Speed 5400 RPM Inlet Pressure Range 5 - 400 PSIG Max Inlet Temperature 316°C Max Exhaust Pressure Condensing to 75 PSIG Overspeed Trip Control System The RLHA28E utilizes the COPPUS snap-acting bolt type trip mechanism. The independent system stops the turbine under any load condition by activating the pneumatically actuated trip valve. It is capable of three consecutive nontrending trips within +/-2% of set trip speed. The Overspeed Trip Collar, installed on the turbine shaft, houses an adjustable, spring loaded bolt. The bolt is retained until a preselected trip speed is reached.
Murray,carrier,coppus, clark,terry, •carbon rings • baffles • bearings • governor single stage steam turbine parts rebuilt skid packages: turbine - gear- governor -generator • labyrinth seals • rotors • blades • brush seals • valve parts • piston cilynder • bushings • tryp pin • seat • rubber inserts • disc. For more than 90 years, COPPUS portable ventilators and cooling products have been recognized as leaders in. • Instruction manuals (pdf) coppus.
Coppus Low pressure, High Volume Single Stage Steam Turbine RLHA28E For over 80 years COPPUS steam turbines have been recognized around the world as rugged, versatile drive solutions for lube oil pumps, feed water pumps, fans, generators and other mechanical drive applications. COPPUS turbines are routinely specified by the petroleum, petrochemical, chemical, sugar, paper, food processing and other industries that require continuous or standby emergency power. The RLHA28E is a specialized single stage steam turbine designed to provide useful power from relatively low pressure, high volume steam conditions.
1 Dresser-Rand RLA Turbine Instruction Manual Feb Revision H 2 3 How to Use This Manual How to Use This Manual THIS MANUAL APPLIES TO RLA-12L, RLA-12M, RLA-16E, RLA-16L, RLA-20L, RLA-22L, AND RLA-23L TURBINES. This instruction manual contains installation, operation, and maintenance instructions for the Dresser-Rand Turbine identified on the Turbine Data Sheet included with this manual. It should be reviewed thoroughly by the user before attempting to install and operate the turbine, and should be kept in a location convenient to the user for ready reference during operation and maintenance. WARNING A complete reading of this manual by personnel in contact with the steam turbine is essential to safety.
It is capable of three consecutive non-trending trip-outs within +/-2% of set trip speed. The Overspeed Trip Collar, installed on the turbine shaft, houses an adjustable, spring loaded bolt. The bolt is retained until a pre-selected trip speed is reached. When the turbine shaft exceeds the selected speed the bolt is instantly released to unlatch the trip valve. The snap-action tripping is positive, precise and repeatable. The Overspeed Trip Valves are designed to minimize pressure drop ensuring the highest available pressure at the nozzle ring for doing work.
This design allows easy access for on-site inspection and repair.
RLVA turbines are designed to meet API 611, NEMA and marine standards. Configurations are available for a wide range of shaft extensions, thrust bearings and flange mounting arrangement. Specifications: Wheel Diameter 12' - 22' Max Power 60 - 1000 HP (44 - 745 kW) Max Speed 4000 - 6000 RPM Max Inlet Pressure 670 - 700 PSIG Max Inlet Temperature 440°C Max Back Pressure 105 - 165 PSIG Inlet Diameter 3/4' - 4' Exhaust Diameter 3' - 8' RLVA Over-speed Trip System Meets API 611 standards The snap-acting bolt type trip mechanism introduced by COPPUS in the mid 80s set new industry standards for Overspeed Trip Systems. The independent system stops the turbine under any load condition by activating the force-actuated trip valve.
Sun saathiya mahiya mp3 free download. This is a small turbine used to drive a pump or fan in industry Steam turbines are HEAT engines They convert the heat energy from steam into mechanical energy that rotates the shaft. Nozzle: First converts heat into kinetic energy by the expansion of the steam. This high velocity steam is directed onto the blades Rotor Blades: Convert this kinetic energy into mechanical work which rotates the shaft Manufacturer Coppus Type Impulse Velocity Compound Horse Power 3 Working Pressure 100 to 180 PSI.
3 Table of Contents.
INCORRECT INSTALLATION, OPERATION, MAINTENANCE, OR PARTS REPLACEMENT CAN RESULT IN INJURY TO PERSONNEL, AND DAMAGE TO THE TURBINE, DRIVEN MACHINERY, AND PLANT. The Instruction Manual consists of 14 sections, as listed in the Table of Contents. Each section is further broken down into subsections. This is a general instruction manual, describing a standard ring oiled turbine with hydraulic Woodward TG governor, the description and illustrations contained herein may differ in minor details from the unit actually supplied, all general installation, operation, and maintenance procedures are applicable.
Pounds per square inch Exhaust Pressure Appx 10 PSI Rotor Diameter 9 inches (23cm). Edmonton Power Historical Foundation Hours of operation The museum is open May 26, July 21 & 22, and Sept 15, 2018. We are also open to groups by appointment. If you wish to arrange a tour please contact us via our contact form or at the postal mailing address. We are located on the grounds of the Leduc West Antique Museum.
Travel 5 miles west of Leduc on Highway 39. Go north on Range Road 260 (Cohne Dale Road) for about a mile and the museum will be on your right.
Coppus Vertical, Radially Split, Single Stage Steam Turbine RLVA For over 80 years COPPUS steam turbines have been recognized around the world as rugged, versatile drive solutions for lube oil pumps, feed water pumps, fans, generators and other mechanical drive applications. COPPUS turbines are routinely specified by the petroleum, petrochemical, chemical, sugar, paper, food processing and other industries that require continuous or standby emergency power. The RLVA turbine offers all the same features as the RLA with the added benefit of the space saving vertical design. Available in 8 frame sizes to meet a wide variety of applications that includes pump drives for on board ships, and pump and fan drives for oil refineries, gas pipelines and other industries where space is limited.
When released by the Overspeed Trip mechanism or the manual trip lever the valve is instantly closed to shut off steam. The single-seated valve will bring a fully, unloaded turbine to a complete stop. For manual resetting against full-line pressure, a pilot valve relieves unbalanced pressure. Standard features on COPPUS Turbines include: Meet or exceed strict API 611 requirements Overspeed mechanical trip valve Snap-acting overspeed trip Woodward TG direct drive oil relay governor Constant level sight-feed oilers Stiff shaft construction with single disc wheel located between bearings Manual speed changer Single piece contoured Curtis type wheel Optional Features for COPPUS Turbines Include: Forged steel wheels Special shaft materials Part load and overload hand valves Kingsbury? Thrust bearings Copper free construction for corrosive atmospheres Single row wheels Lagging, 'blanket type' insulation High back pressure construction Electronic or hydraulic NEMA Class D governors and variable speed controls Solenoid trips for remote shutdown Extended inlet pressure and temperature constructions © 2004 - 2018 All rights reserved. Hosted & Created.
NOTE If there is a CE mark on this turbine nameplate it indicates compliance with the ATEX Directive. Machinery Directive Compliance and Machinery Directive CE marking of the turbine and driven equipment is the responsibility of the assembler or installer. See the Machinery Directive Declaration of Incorporation. NOTE Refer to the Machinery Directive - List of Residual Risks and the ATEX Directive-Risk Assessment Summary List for warnings related to EU Compliance. Additional cautions and warnings are located throughout this manual and in the safety precautions section.